This work aim to study the effect of transverse reinforcement , area of splice
bar, concrete cover thickness , rib area and the increasing in concrete strength (highstrength
concrete) on bond strength between concrete and reinforcing spliced bars .
Therefore, a new simple equation is derived for beams with spliced bars and
confined by transverse reinforcement to calculate bond strength and reflects the
effects of these factors .Where many of existing codes and provisions used to
calculate the spliced strength do not include or reflect the influencing of these factors
in bond strength estimation . Based on experimental results from previous works ,
(116) confined beams with spliced bars are investigated in this study , where
concrete compressive strength ( c f ¢
) ranging from 25 MPa to 113.793 MPa ,amount
of transverse reinforcement vary in a wide range and , conventional and high
relative rib area of deformed bars are present in these beams . The proposed method
exceed the limitation of ( f MPa c ¢ £ 69 ) that given by ACI code .Where the
proposed method is examined and applicable for concrete compressive strength up
to 113 MPa . Also, in this work the second root of c f ¢
is examined , as concrete
strength increased with high-strength concrete , to reach a suitable value for both
normal and high- strength concrete and to be more appropriate with the heavy
present of transverse reinforcement . Power of (0.35) is adopted and used in this
work instead of the second root of c f ¢